Background:
Because there are many components in motion, we've compiled a list outlining requirements, clarifications, and areas of responsibility to ensure the seamless integration between Inlet and the lock system.
Read more about the security principals for Inlet and the connections to locks here.
Practical and Technical Requirements:
-
The locksmith installs the locks and the installer/technician installs/configures the access control system.
-
The IT provider supplies the server where the access control system/IEC software can be installed and secures the server with a firewall and access control. See at the bottom of this article for the specifications.
-
The installer/technician installs the access control system/IEC on the server and configures the access control system (controllers, door environments, readers, etc). The access zones and readers to be used by Inlet must be configured and available to the integration operator.
-
The IEC2 licence is ordered and entered by the installer/technician. The standard Inlet integration requires an IEC2 Advanced licence or an IEC2 Inlet licence. Both IEC2 licence options cover the same functionality toward Inlet. An existing IEC2 Advanced licence can be used; a separate IEC2 Inlet licence is not needed in addition. IEC2 Basic is not sufficient for the standard integration. Any limited alternative using PGIN must be agreed with Inlet separately before setup. Confirm the applicable IEC2 licence and price with the supplier.
-
The technician creates a dedicated user/operator for Inlet in the access control system and maps it to a SessionToken in the IEC2 Config GUI (IDA - Ida.Server.Config.exe). The operator must have the permissions needed to manage users, readers, and locks via the API, including access to the relevant zones and readers. The IEC2 licence and operator permissions are separate requirements; the IEC2 licence alone does not grant these permissions.
-
HTTPS is activated in the IDA Config GUI and certificates are connected. (See separate manual)
-
Configurations: See manual - 1-986-4115-GB Data Services - IDA Plug Ins.pdf. Use the documentation matching the installed Integra/IEC version. For an installation using Inlet's SOAP integration, confirm that the SOAP service is enabled and reachable. Where IEC.CompatibilityWrapper is used, provide its SOAP endpoint rather than a REST-only endpoint. Confirm the protocol and full endpoint with Inlet before commissioning.
-
The IT provider ensures whitelisting of IP addresses and sets up port forwarding from the external port to the internal port to the server so that we can access the API.
-
See at the bottom for IP addresses and ports.
- Inlet needs receive the following to email support@inlet.tech:
- Use secure sendig via PrivateBin or other secure mode of transport
- Customer Name
- Information on what locks and lock groups Inlet should set up, including the relevant access zones and readers.
- IEC session token in the format (4f72ba45-49bf-1sr2-v442-f5t54896k23b)
- Public URL or static IP address to the server, including the full API endpoint, port and protocol.
- Installed Integra/IEC version and confirmation of either an IEC2 Advanced licence or an IEC2 Inlet licence.
- Inlet retrieves IDs of the card reader objects and confirms the relevant zones/readers with the installer to configure Inlet with the access control system.
- Inlet will inform the top system/booking system that they can test.
- Inlet requires at least 2 weeks of testing with the top system/booking system after the installer/provider has completed points 1-8.
IP addresses that need to be whitelisted:
Required: 52.164.185.179 and 77.110.204.178
Ports that need to be mapped:
The standard endpoint address is 9000 (http/https). The port can be changed if desired. (Change via Ida.Server.Config.exe, see manual "1-986-4115-GB Data Services - IDA Plug Ins.pdf" )
Access System Server IP Address Configuration:
A static IP address should be assigned to prevent it from being changed during a restart, and causing downtime due to the mapping in the previous point